Overview

The UltraScan PRO is designed to be your reference instrument for measuring both reflected and transmitted color. It meets CIE, ASTM and USP guidelines for accurate color measurement. The instrument’s 5 nm optical resolution enables it to precisely measure colors using colorants with sharp cutoff characteristics.

Ideal for demanding research and quality control applications.
The D65 illumination source is calibrated in the ultraviolet region for the accurate measurement of whitening agents. UltraScan PRO has an extended wavelength range into the near infrared and near ultraviolet that permits the measurement of camouflage materials and UV blockers. The system uses diffuse/8° geometry with automated specular component inclusion/exclusion. It also features three sizes of sample measurement areas with automated lens change. The UltraScan PRO includes EasyMatch QC software and an electronic record keeping version that is 21 CFR 11 compliant is available.

Use UltraScan PRO for both research and quality control. From opaque solids to clear liquids to transparent films, UltraScan PRO precisely measures both reflected and transmitted color, spectral reflectance, spectral transmittance and transmission haze. A host of measurement features and specialized sample-handling devices make UltraScan PRO the most versatile high-performance color measurement benchtop spectrophotometer available.

Explore all the additional features and benefits below.

FEATURES

Measures reflectance & transmittance color as well as spectral reflectance, spectral transmittance and transmission haze

Wavelength range 350 nm – 1050 nm

5 nm optical resolution and reporting interval

Three reflectance measurement areas

Exceptional inter-instrument agreement

Automated UV calibration and control

Large transmission compartment open on three sides

Includes EasyMatch QC software

PRODUCT SPECIFICATIONS

Measurement Principle: Dual-beam spectrophotometer/colorimeter

Geometry: Diffuse d/8° reflectance, d/8° total transmission, d/0° regular transmission

Spectrophotometer/Colorimeter: Two polychromators, each with a 512 element diode array and a high resolution, concave holographic grating

Sphere Diameter: 152 mm (6 in.)

Sphere Coating: Spectraflect™ for sphere, Duraflect™ for port plate and specular exclusion door

Port Size/Measured Area:

  • Port Diameter/View Diameter in RSIN/RSEX reflectance modes
    • Large Area View (LAV): 25 mm (1 in) illuminated/19 mm (0.75 in) measured
    • Medium Area View (MAV): 13 mm (0.5 in) illuminated/9 mm (0.35 in) measured
    • Small Area View (SAV): 7 mm (0.25 in) illuminated/4 mm (0.16 in) measured
  • Port Diameter/View Diameter in TTRAN transmittance modes
    • Large Area View (LAV): 25 mm (1 in) illuminated/17.4 mm (0.69 in) measured
    • Medium Area View (MAV): 25 mm (1 in) illuminated/13.2 mm (0.52 in) measured
    • Small Area View (SAV): 25 mm (1 in) illuminated/11.6 mm (0.46 in) measured
  • Port Diameter/View Diameter in RTRAN transmittance mode where lens is field stop for all areas of view
    • Large Area View (LAV): 17 mm (0.67 in) illuminated/17 mm (0.67 in) measured
    • Medium Area View (MAV): 17 mm (0.67 in) illuminated/17 mm (0.67 in) measured
    • Small Area View (SAV): 17 mm (0.67 in) illuminated/17 mm (0.67 in) measured

Lens Switching for LAV/MAV/SAV: Automatic

Specular Component: Automated Included (RSIN) or Excluded (RSEX) in reflectance

Spectral Range: 350 nm – 1050 nm full CIE visible range plus NIR

Wavelength Resolution: < 2 nm

Effective Bandwidth: 5 nm equivalent triangular

Reporting Interval: 5 nm

Photometric Range: 0-150 %

Light Source: Pulsed Xenon lamps (3), calibrated and controlled in the UV range

Automatic UV Control:

  • 400 nm cutoff filter for UV control and UV exclusion
  • Optional 420 nm cutoff filter for UV exclusion

Transmission Modes: Total (TTRAN) and Regular (RTRAN)

Transmission Compartment:

  • Large and open on 3 sides
  • 10.2 cm D X 35.6 cm W x 16.5 cm H (4 in. D x 14 in. W x 6.5 in. H)

Standards Conformance

  • Reflectance: CIE 15:2004, ISO 7724/1, ASTM E1164, DIN 5033, Teil 7 and JIS Z 8722 Condition C
  • Transmittance: CIE 15:2004, ASTM E1164, DIN 5033 Teil 7 and JIS Z 8722 Condition E, G Haze conformance per ASTM D1003 Section 8. Procedure B Spectrophotometer

Standards Traceability: Instrument standard assignment in accordance with National Institute of Standards and Technology (NIST) following practices described in CIE Publication 44 and ASTM E259